Allied-telesis AT-PWR3101 User Manual

Browse online or download User Manual for Computer hardware Allied-telesis AT-PWR3101. Allied Telesis AT-PWR3101 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - AT-PWR3101

AT-RPS3104AT-PWR3101Redundant Power Supply Systemand Power Supply Modulefor the AT-8524POE Layer 2+Fast Ethernet SwitchInstallation GuidePN 613-50680-

Page 2

Preface10

Page 3 - Compliance Statement

11Installation InstructionsThe AT-RPS3104 system is a redundant power supply (RPS) for the AT-8524POE Layer 2+ Fast Ethernet switch with Power over Et

Page 4

Installation Instructions12IntroductionThe AT-RPS3104 system comes with one pre-installed AT-PWR3101 power supply module and features three empty slot

Page 5 - Contents

AT-RPS3104 and AT-PWR3101 Installation Guide13AT-PWR3101 Module’s Operating ModesThe AT-PWR3101 module is not a load-sharing RPS unit. During normal o

Page 6 - Appendix B

Installation Instructions14AT-PWR3101 Module LEDThe AT-PWR3101 module has one LED labelled STATUS. The meanings of the LED states are described below:

Page 7

AT-RPS3104 and AT-PWR3101 Installation Guide15Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install t

Page 8 - Document Conventions

Installation Instructions16CautionAll Countries: Install this product in accordance with local and National Electric Codes.  11CautionCircuit Overloa

Page 9 - Contacting Allied Telesyn

AT-RPS3104 and AT-PWR3101 Installation Guide17Verifying Package ContentsVerify that the following components are included in the AT-RPS3104 shipping c

Page 10

Installation Instructions18Mounting the AT-RPS3104 in a RackThe AT-RPS3104 system can be installed on a table or in a standard 19-inch rack. This sect

Page 11 - Installation Instructions

AT-RPS3104 and AT-PWR3101 Installation Guide192. Attach a rack-mount bracket to one side of the front of the system using a # 1 Phillips screwdriver a

Page 12 - Introduction

Copyright © 2004 Allied Telesyn, Inc.www.alliedtelesyn.comAll rights reserved. No part of this publication may be reproduced without prior written per

Page 13

Installation Instructions20Installing the Power Cord Retaining ClipsIncluded with the switch are four power cord retaining clips. The clips secure the

Page 14 - AT-PWR3101 Module LED

AT-RPS3104 and AT-PWR3101 Installation Guide21To facilitate the installation and removal of AC power cables, the clips of adjoining AC connectors shou

Page 15 - Reviewing Safety Precautions

Installation Instructions22Cabling the AT-RPS3104 SystemTo cable the AT-RPS3104 system, do the following:1. Verify that the On/Off switch for the pre-

Page 16

AT-RPS3104 and AT-PWR3101 Installation Guide233. Slide over the retaining clip to secure the power cord (see Figure 10).Figure 10. Securing the Power

Page 17 - Verifying Package Contents

Installation Instructions245. Plug one end of a 17-pin D-combo connector RPS cable into the connector labeled “RPS INPUT” on the rear panel of the AT-

Page 18

AT-RPS3104 and AT-PWR3101 Installation Guide257. Plug the other end of the RPS cable into the connector labeled “RPS OUTPUT A” on the back of the AT-R

Page 19

Installation Instructions269. Turn the On/Off switch for Slot A on the back panel of the AT-RPS3104 system to the On position (see Figure 8 on page 22

Page 20

AT-RPS3104 and AT-PWR3101 Installation Guide27Installing an AT-PWR3101 ModuleBefore installing an additional AT-PWR3101 module in an AT-RPS3104 system

Page 21 - AC INPUT

Installation Instructions284. Slide the new AT-PWR3101 module into the expansion slot (see Figure 16).Figure 16. Installing the AT-PWR3101 Module5. Pr

Page 22 - Cabling the AT-RPS3104 System

AT-RPS3104 and AT-PWR3101 Installation Guide296. Using a # 1 Phillips screwdriver, tighten the two captive screws to secure the module in the AT-RPS31

Page 23 - 100-240VAC

3Electrical Safety and Emission Compliance StatementStandards: This product meets the following standards.RFI Emission FCC Class A, EN55022 Class A, V

Page 24 - RPS INPUT

Installation Instructions308. Slide over the retaining clip to secure the power cord (see Figure 19).Figure 19. Securing the Power Cord with the Retai

Page 25

AT-RPS3104 and AT-PWR3101 Installation Guide3110. Tighten the thumb screws on the connector to secure the cable to the switch (see Figure 21).Figure 2

Page 26

Installation Instructions3214. Check the STATUS LED on the front panel of the AT-PWR3101 module. It should be green. If the LED is off, repeat this pr

Page 27

AT-RPS3104 and AT-PWR3101 Installation Guide33Replacing the AT-PWR3101 ModuleTo remove or replace a failed AT-PWR3101 module, perform the following pr

Page 28

Installation Instructions343. Using the handle on the faceplate of the AT-PWR3101 module, pull the module from the system (see Figure 24).Figure 24. R

Page 29

AT-RPS3104 and AT-PWR3101 Installation Guide354. If you are not replacing the failed module with a new AT-PWR3101 module, reinstall the blank faceplat

Page 30

Installation Instructions367. Slide the module into the expansion slot in the AT-RPS3104 system (see Figure 26).Figure 26. Installing the AT-PWR3101 M

Page 31

AT-RPS3104 and AT-PWR3101 Installation Guide379. Using a # 1 Phillips screwdriver, tighten the two captive screws to secure the module in the AT-RPS31

Page 32

Installation Instructions38

Page 33

39Appendix ATechnical SpecificationsPhysicalDimensions:AT-RPS3104 6.35 cm x 43.8 cm x 40.6 cm(2.50 in. x 17.25 in. x 16.0 in.)(H x W x D)Weight:AT-RP

Page 34

Electrical Safety and Emission Compliance Statement4Belangrijk: Appendix B bevat vertaalde veiligheidsopmerkingen voor het installeren van deze appara

Page 35

Appendix A: Technical Specifications40Electrical RatingAT-RPS3104 System 100-240 VAC, 7.0A maximum, 50/60 Hzmaximum per inputAgency CertificatesEMI: F

Page 36

AT-RPS3104 and AT-PWR3101 Installation Guide41Table 2 lists the RPS connector pins and definitions.Table 2. Pin Definitions for the RPS Connectors on

Page 37

Appendix A: Technical Specifications42

Page 38

43Appendix BTranslated Electrical Safety and Emission InformationImportant: This appendix contains multiple-language translations for the safety state

Page 39 - Technical Specifications

Appendix B: Translated Electrical Safety and Emission Information44Standards: This product meets the following safety standards. 1 RFI Emission FCC C

Page 40 - RPS Connector Port Pinouts

AT-RPS3401 and AT-PWR3101 Installation Guide45 6 LIGHTNING DANGERDANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY. 7

Page 41

Appendix B: Translated Electrical Safety and Emission Information46Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochf

Page 42

AT-RPS3401 and AT-PWR3101 Installation Guide47Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemissio

Page 43 - Information

Appendix B: Translated Electrical Safety and Emission Information48Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie FCC Klasse A, EN5

Page 44

AT-RPS3401 and AT-PWR3101 Installation Guide49 10 BEDRIJFSTEMPERATUUR: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden

Page 45

5ContentsElectrical Safety and Emission Compliance Statement ... 3Preface ...

Page 46

Appendix B: Translated Electrical Safety and Emission Information50Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférence

Page 47

AT-RPS3401 and AT-PWR3101 Installation Guide51 11 POUR TOUS PAYS: Installer le matériel conformément aux normes électriques nationales et locales.

Page 48

Appendix B: Translated Electrical Safety and Emission Information52Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirint

Page 49

AT-RPS3401 and AT-PWR3101 Installation Guide53Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequ

Page 50

Appendix B: Translated Electrical Safety and Emission Information54 11 TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative el

Page 51

AT-RPS3401 and AT-PWR3101 Installation Guide55Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling FCC Klasse

Page 52

Appendix B: Translated Electrical Safety and Emission Information56Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de

Page 53

AT-RPS3401 and AT-PWR3101 Installation Guide57 11 TODOS OS PAÍSES: Instale o produto de acordo com as normas nacionais e locais para instalações elét

Page 54

Appendix B: Translated Electrical Safety and Emission Information58Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI FCC

Page 55

AT-RPS3401 and AT-PWR3101 Installation Guide59 11 PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionale

Page 56

Contents6Appendix BTranslated Electrical Safety and Emission Information... 43

Page 57

Appendix B: Translated Electrical Safety and Emission Information60Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning FCC Klas

Page 58

7PrefaceThis guide contains installation instructions for the AT-RPS3104 redundant power supply (RPS) system and the AT-PWR3101 power supply module.No

Page 59

Preface8Document ConventionsThis guide uses the following conventions:NoteNotes provides additional information.CautionCautions indicate that performi

Page 60

AT-RPS3104 and AT-PWR3101 Installation Guide9Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support

Related models: AT-RPS3104

Comments to this Manuals

No comments