Problem Solving
10
Problem Solving
Is the unit receiving
power?
Check the POWER LED on the front of the hub. This green LED should be
lit.
If the power LED is not on:
1. Check the back of the unit. Make sure the power cord is attached
securely.
2. Check the AC power adapter. Make sure the power adapter is plugged
into a functioning wall outlet and that it is properly inserted into the
hub’s power connector on the back of the unit.
Is the Link/Activity
LED lit?
The Link LED on the front of the hub lights when a proper connection
between the corresponding 10/100Base-TX port and the equipment
connected to it is established. If this LED is not lit, check for the problems
listed below and make corrections as necessary.
1. Problem 1:
The cable has been cut, damaged, or it is the wrong type of cable.
Solution 1:
— Try making the connection with a different cable. Be sure
you are using an undamaged cable of the correct type.
2. Problem 2:
Connected equipment is not turned on or not operating properly.
Solution 2:
— Check the connected equipment (computer, another hub,
etc.) and turn on the power.
3. Problem 3:
The MDI button is in the wrong setting.
Solution 3:
— When using the cascade port of the hub, you should set the
button to the
To HUB
position; otherwise, the button
should be in the
To PC
position.
— When cascading two hubs, the unit using the cascade port
should have the button set to the
To HUB
position, while
the other unit should have its switch set to
To PC
.
— When ports with associated MDI buttons are not connected
to other hubs but are used to connect to workstations or
other equipment, you should set the MDI button to the
To
PC
position.