A5 Installation and Safety Guide CoverAT-8600 Series SwitchInstallation and Safety GuideAT-8624T/2MAT-8624PoEAT-8648T/2SP
Installation & Safety Guide 9Figure 2: AT-8624PoE front and rear panel with AC power inletFigure 3: AT-8648T/2SP front and rear panel with AC powe
10 AT-8600 Series SwitchConnecting the SwitchSome configuration is necessary to enable the switch’s advanced switching capabilities. This is achieved
Installation & Safety Guide 115. Configure online help.Before using online help, you must configure the help file by using the command:set help=&l
12 AT-8600 Series Switch2. Connect the PC to the switch.Use an Ethernet cable to connect an Ethernet card on the PC to any one of the switch ports.You
Installation & Safety Guide 13Checking LEDsThe following tables outline how the switch and expansion modules report faults and operational activit
14 AT-8600 Series SwitchLink and Mode LEDs for the AT-8624T/2M switchLED State DescriptionLINK Off There is no link between the port and the end-node.
Installation & Safety Guide 15Link and Mode LEDs for the AT-8624PoE switch LED State DescriptionL/A Status (Top LED)Off There is no link between t
16 AT-8600 Series SwitchLink and Mode LEDs for the AT-8648T/2SP switch LED State DescriptionLINK Off There is no link between the port and the end-nod
Installation & Safety Guide 17SFP and 10/100/1000Base-T LEDs for the AT-8648T/2SP switch LED State DescriptionLINK Off There is no link between th
18 AT-8600 Series SwitchObtaining Documentation and ResourcesThe complete document set for the AT-8600 Series switches includes: This Installation &
AT-8600 Series Installation & Safety GuideAT-8624T/2M AT-8624PoE AT-8648T/2SPDownload the complete document set from www.alliedtelesis.com/support
Installation & Safety Guide 19StandardsWhere applicable, the products in this document meet the following standards:Category Approval Agency and R
20 AT-8600 Series SwitchSafetyWARNING: In a domestic environment this product may cause radio interference in which case the user may be required to t
Installation & Safety Guide 21Lithium Battery - Should only be changed by authorised service personnel. CAUTION: Danger of explosion if battery in
22 AT-8600 Series SwitchVORSICHT: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN.GERÄTE DE
Installation & Safety Guide 23SikkerhedADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræ
24 AT-8600 Series SwitchLithium batteri - Bør kun udskiftes af uddannet og kvalificeret tekniker. ADVARSEL : Eksplosionsfare, hvis batteriet udskiftes
Installation & Safety Guide 25BEDRIJFSTEMPERATUUR: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.ELEKTRISC
26 AT-8600 Series SwitchÉQUIPEMENT DE CLASSE 1 ÉLECTRIQUE CE MATÉRIEL DOIT ÊTRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise
Installation & Safety Guide 27SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyt
28 AT-8600 Series SwitchNorme di SicurezzaAVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potreb
2 AT-8600 Series SwitchAT-8600 Installation & Safety Guide Document Number C613-000083 REV H© 2006-2011 Allied Telesis Inc. All rights reserved. N
Installation & Safety Guide 29ATTENZIONE: CARICAMENTO MECCANICO - Il montaggio del dispositivo sul supporto va effettuato in maniera tale da evita
30 AT-8600 Series SwitchFORSIKTIG: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med romtemperatur for avkjøling.DRIFTSTEMPERATUR: D
Installation & Safety Guide 31ELÉTRICO - EQUIPAMENTOS DO TIPO CLASSE 1 DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue de alim
32 AT-8600 Series SwitchSeguridadADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse
Installation & Safety Guide 33ATENCION: CARGA MECANICA - El montaje del equipo en el bastidor debe realizarse de manera tal que no cause una condi
34 AT-8600 Series SwitchDRIFTSTEMPERATUR: Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.ELEKTRISKT - ÖVERBELASTNIN
Installation & Safety Guide 3Table of ContentsModels Covered by this Guide ...
4 AT-8600 Series SwitchModels Covered by this GuideThis document includes information about the following switches: AT-8624T/2M 24-port 10BASE-T/100B
Installation & Safety Guide 5Selecting a SiteBefore you install the switch, review the following considerations about its location. The switch re
6 AT-8600 Series SwitchInstalling the SwitchPorts on the switch are suitable only for connections within buildings (intra-building) and with cables un
Installation & Safety Guide 7Procedure1. If you have any optional expansion modules, install them first.The AT-8600 Series switches support the AT
8 AT-8600 Series Switch. Slide the transceiver into the SFP socket, and firmly press it until it engages. To remove it, first release it by gently pul
Comments to this Manuals