Installation
34
Installing the Switch on a Desktop
The switch can be installed in a standard 19-inch rack or on a table or
desktop. To install the switch in a rack, go to the section Installing the
Switch in a Rack on page 36. To install the switch as a table or desktop,
perform the following steps:
1. Remove all components from the shipping package and store the
packaging material in a safe location.
2. Locate a level, secure surface for the switch.
3. If you purchased an expansion module for the switch, install the
module by following the instructions in the section Installing an
Expansion Module on page 38.
4. If you purchased a redundant power supply (RPS) unit for the switch,
connect the RPS unit to the R.P.S. Input connector (Figure 4) on the
rear of the switch by following the directions included with the RPS
system.
Note
If you intend to use a redundant power supply (RPS) with the
switch, check to be sure that the cable with the RPS unit is
compatible with the RPS Input Port on the switch. The pin
assignments for the connector are provided in Appendix A.
5. Apply AC power to the switch by plugging the power cord into the AC
power connector on the back panel of the unit (shown in Figure 4)
and plugging the other end into a wall outlet.
Figure 4 Switch Rear Panel
Warning
The power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. "
10
AC Power Connector
RPS Connector