  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
Quick Install Guide 7
C613-04040-01 REV B
Figure 2: AT-RPS9000 rear panel.
8. Apply power to the AT-PWR9000.
There are two AC inputs on the chassis’s rear panel (see Figure 2 on
page -7). Input A feeds the two bays that supply RPS outputs A1 and A2,
while input B feeds the bays that supply outputs B1 and B2.
Use the provided AC power cord(s) to connect the appropriate bays (bays
that have installed AT-PWR9000 units) to a mains power supply.
9. Activate the RPS output(s).
There are four standby switches on the chassis’s rear panel, one for each
RPS output (see Figure 2 on page -7). Press the standby switch that is
closest to the RPS output you want to activate.
10. Check the RPS and switch LEDs.
RPS and AT-9812T or AT-9816GB switch LEDs indicate the system’s
operational status. See the following section for details.
AT-9800 Series switches have the following power supply related LEDs.
AC INPUT A
AC INPUT
100-240V
HZ
50/60
AMPS
5.0-2.5
AC INPUT B
AC INPUT
100-240V
HZ
50/60
AMPS
5.0-2.5
RPS OUPUT A1
RPS OUPUT A2
RPS OUPUT B1 RPS OUPUT B2
OUTPUT VDC A Max
16
16
0.5
+3.3
+5
+12
OUTPUT VDC A Max
16
16
0.5
+3.3
+5
+12
OUTPUT VDC A Max
16
16
0.5
+3.3
+5
+12
OUTPUT VDC A Max
16
16
0.5
+3.3
+5
+12
AT-RPS9000
AC Input A
(For RPS output A1 & A2)
AC Input B
(For RPS output B1 & B2)
RPS Output A1 RPS Output A2 RPS Output B2RPS Output B1
Power Switches
LEDs and Troubleshooting
AT-PWR9000 units have one LED.
Table 1: AT-PWR9000 LED.
LED State Function
Power Green The PWR is receiving AC power and the voltage
is within an acceptable range
Table 2: Power supply related LEDs found on all AT-9800 Series Switches.
LED State Function
PWR
(Power)
Green The switch is receiving power
Page view 6