Allied-telesis AR700 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Features in 281-01 8
Version 281-01
C613-10482-00 REV A
CR00012613
Firewall 2 When the WAN load balancer was used with IP NAT (instead of firewall NAT), and
an FTP session was established to a server on the public network, the router did
not correctly establish a return session. This meant data was unable to flow
correctly back from the server, and the router rebooted.
This issue has been resolved.
Note that the WAN load balancer is not designed for use with IP NAT, because IP
NATs are not associated with interfaces. Configurations that use an IP NAT cannot
vary the global IP address (the gblip parameter) based on the outgoing interface,
so the WAN load balancer sends all traffic out with the same source address.
Therefore, the return traffic probably comes back via the WAN load balancer
resource that is associated with the global IP. The impact is that the WAN load
balancer balances the outgoing traffic but not the return traffic.
We recommend using firewall NAT instead of IP NAT with the WAN load balancer.
Y-Y-------
CR00012624
VRRP,
IP Gateway
2 Under certain network conditions in which VRRP entities become temporarily
unsynchronised, the router or switch could receive a gratuitous ARP from a self-
elected VRRP master when the router or switch was still the master. This caused
the existing master to create an ARP entry that incorrectly redirected packets
towards the other VRRP entity even after the other entity had become a slave
again.
This issue has been resolved. The router or switch no longer accepts gratuitous
ARPs from other VRRP entities while it is still the Master.
YYYYYYYYYY
CR00012683
Switch 2 After the AR770S rebooted, the Port Link/Activity and Duplex/Collision LEDs
sometimes did not blink in response to activity and collisions, respectively.
This issue has been resolved. The router detects the problem and recovers from
it, if possible. If it cannot recover from the problem, it generates a log message
of severity 6, module SWK, type REST, and subtype FAIL. The log message says
“An LED error has been detected, please power-cycle the device. If this message
appears again, contact your technical support representative for help.”
--Y-------
CR Module Level Description
AR400
AR7x5
AR750S / AR770S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948 / x900-48
AT-9900
AT-9800
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 21 22

Comments to this Manuals

No comments