AT-FS20x Series Installation Guide
5
The back panel of the AT-FS201, AT-FS202, and AT-FS202SC/FS1
Bridging Media Converters features a DC power connector and DIP
switches for manually configuring the ports.
Figure 7 shows the back panel of the AT-FS201, AT-FS202, and
AT-FS202SC/FS1 Bridging Media Converters with a 12VDC power
connector.
Figure 7. Back Panel of the AT-FS201, AT-FS202, and AT-FS202SC/FS1
Bridging Media Converters (12VDC Power Connector)
Table 1 lists the maximum operating distances for the converters.
Table 1. Maximum Operating Distances
Model
100Base-FX
10Base-T/100Base-
TX
Connect
or
Maximum
Operating
Distance
1
1. Maximum distance for 100 Mbps optical datalinks is dependent on the follow-
ing factors: type of optical fiber, duplex mode of both end-nodes, and maximum
optical loss budget for each of the optical fiber at the operating optical wave-
length.
Connect
or
Maximum
Operating
Distance
2
2. Maximum distance can only be obtained when the UTP/STP cabling is
installed and verified to TIA/EIA 568A Commercial Building Telecommunica-
tions Cabling Standard.
AT-FS201 Dual ST 2 km
(1.24 mi)
RJ-45 100 m
(328 ft)
AT-FS202 Dual SC 2 km
(1.24 mi)
RJ-45 100 m
(328 ft)
AT-FS202SC/FS1 Dual SC 15 km
(9.4 mi)
RJ-45 100 m
(328 ft)
12 V D C
21 34
1222
PORT
10
100
HALF
FULL
OFF
ON
DUPLEX
MODE
AUTO
NEG
SPEED
(Mbps)
Page view 14