AT-S81 Management Software User’s Guide
Section I: Using the Menus Interface 105
Port
Prioritization for
Power Allocation
The AT-S81 management software also allows you to prioritize the ports in
the event that the powered devices require more power than the switch
can deliver. This feature ensures that the most important powered devices
connected to the switch are guaranteed to have power.
If the powered devices connected to the switch require more power than
the switch is capable of delivering, the switch denies power to some ports
based on a system called port prioritization. You can use this system to
ensure that powered devices that are critical to your network are given
preferential access to the available power.
There are three priority levels:
Critical
High
Low
Ports designated as critical receive power before any other ports with a
lower priority. Always assign the critical priority level to your most
important network devices. If there is not enough power to support all the
ports set to the critical priority level, then power is provided to the ports
based on port number, in ascending order.
Ports set to the high level receive power only after all the critical ports
receive their power. If there is not enough power to support all the ports
set to the high priority level, then power is provided to the ports based on
port number, in ascending order.
The lowest priority setting is low, the default setting for all ports. Ports with
low priority receive power only after the critical and high level ports receive
their power. If there is not enough power to support all the ports set to the
high priority level, then power is provided to the ports based on port
number, in ascending order.
PoE Device
Classes
The IEEE 802.3af standard specifies four classes for powered devices
based on their power usage. The classes are defined in Table 2.
Table 2. Power Classes for Powered Devices
Class Power Usage
0 (Default) 0.44 W to 12.95 W
1 0.44 W to 3.84 W
2 3.84 W to 6.49 W
3 6.49 W to 12.95 W
Page view 104