Chapter 3
Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
Note
If you change the speed or duplex mode of a port on the converter
using the DIP switches, you must power OFF and then power ON
the unit to activate the change.
If the PWR LED is OFF, do the following:
If the converter is installed on a desktop, check to be sure that the
power adapter is securely connected to a power outlet and that
the power adapter cable is securely connected to the back of the
converter.
If the converter is installed in an AT-MCR12 chassis, check that
the unit is fully seated in the slot and the retaining screw is
securely fastened.
Verify that the power outlet has power by connecting another
device to it.
Try using another power adapter.
If the LNK/ACT LED for the twisted pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON
and is operating properly.
Check that the twisted pair cable is securely connected to the
twisted pair port on the converter and on the end-node.
Check that the end-nodes connected to the switch are operating
in the same duplex mode.
Make sure that the twisted pair cable does not exceed 100
meters (328 feet) and that you are using a Category 3 or better
Page view 40