Chapter 2: Installation
54
Starting a local management session
This procedure requires a terminal or a terminal emulator program and the
management cable that comes with the switch. To start a local
management session on the switch, perform the following procedure:
1. Connect the RJ45 connector on the management cable to the console
port on the front panel of the switch, as shown below.
FIGURE 25. CONNECTING THE MANAGEMENT CABLE TO THE CONSOLE PORT
OF AN X230 SERIES SWITCH
x230-10GP
CONSOLE
RS-232
SD
FAULT
POWER
SD
1000 LINK
ACT
10/100 LINK
ACT
2 4
13
MAC Address Label
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None